Transformers
Q: Do you manufacture low-frequency custom transformers?
A: Yes. We make low-frequency laminated transformers. For more information, please contact our sales and technical team at This email address is being protected from spambots. You need JavaScript enabled to view it. .
Q: What is the output power range of your low-frequency custom transformers?
A: The output power range of our custom transformers is 5 watts to 10,000 watts.
Q: What is the operational frequency range of your low-frequency custom transformers?
A: The operational frequency range is 8 Hz to 2K Hz.
Q: What is the output voltage range of your low-frequency custom transformers?
A: The output voltage range is 0.5 V rms. to 5K V rms.
Q: What is the output current range of your low-frequency custom transformers?
A: The output current range is 0.1 A rms. to 800 A rms.
Q: How do I order custom transformers of your low-frequency custom transformers?
A: To ensure the transformer is built precisely to your needs, please provide the following specifications so that we can provide you a quotation with price and lead time:
- Primary Voltage (V rms.)
- Secondary Voltage (V rms.)
- Output Power (W)
- Operation Frequency (Hz)
Q: Do you make high voltage high frequency transformers?
A: Yes, we manufacture high frequency high voltage output transformers. You can view our standard product list here
-> https://www.amp-line.com/products/high-frequency-output-transformers
Q: What is the frequency range of your high-frequency transformers?
A: The frequency range of our high-frequency transformers is sections of 20 Hz to 800K Hz.
Q: What is the output power range of your high-frequency transformers?
A: The output power range of our high-frequency transformers is 5 W to 10,000 W.
Q: What is the output voltage range of your high-frequency transformers?
A: The output voltage range is 0.5 V rms. to 10,000 V rms.
Q: What is the output current range of your high-frequency transformers?
A: The output current range is 0.01 A rms. to 800 A rms.
Q: What is the standard primary voltage?
A: The standard primary voltage is 25 V rms. unless otherwise specified.